SMF VRLA Range - Exide Powersafe EP range The NEW Improved Exide Powersafe, Sealed maintenance free VRLA batteries comes with enhanced design features, which give a higher performance & reliability, better suited to Indian conditions. |
|
TECHNICAL SPECIFICATION |
Battery Type |
Nominal Voltage (V) V / cell |
Rated Capacity (Ah) at 27'C
20 hr 1.75 + 2 |
Dimensions in mm |
Weight (kg) |
Overall Height top + 2 |
Length +1 |
Width +1 |
EP 7 - 12 |
12 |
7 |
100 |
151 |
65 |
2.2 |
EP 9 - 12 / EP 1234 W |
12 |
9 |
100 |
151 |
65 |
2.4 |
EP 12 - 12 |
12 |
12 |
100 |
151 |
98 |
3.2 |
EP 17 -12 |
12 |
17 |
167 |
181 |
76 |
5.0 |
EP 26 - 12 W |
12 |
26 |
175 |
166 |
125 |
8.6 |
EP 42 - 12 |
12 |
42 |
170 |
197 |
165 |
14.0 |
EP 65 - 12 |
12 |
65 |
174 |
350 |
166 |
20.2 |
EP 75 - 12 |
12 |
75 |
174 |
350 |
166 |
21.9 |
EP 100 - 12 |
12 |
100 |
235 |
407 |
173 |
32.2 |
EP 120 - 12 |
12 |
120 |
235 |
407 |
173 |
34.6 |
EP 150 - 12 |
12 |
150 |
240 |
557 |
172 |
44.8 |
EP 200 -12 |
12 |
200 |
240 |
533 |
250 |
66.1 |
. |
|
|
|
|
|
|
|
|
 |
|
SMF VRLA Range - Exide Powersafe NXT range After 10 years of experience in VRLA with Shine Kobe, Exide has finally launched the Exide Powersage NXT with the cycle life unmatched with competition nationally and internationally with the range its unique features of 5 hours quick recharge option. |
|
TECHNICAL SPECIFICATION |
Battery Type |
Nominal Voltage (V) V / cell |
Rated Capacity (Ah) at 27'C
20 hr 1.75 + 2 |
Dimensions in mm |
Weight (kg) |
Overall Height
+ / - 3 |
Length + / - 2 |
Width + / - 2 |
NXT 17 - 12 |
12 |
17 |
167 |
181 |
76 |
5.90 |
NXT 26 - 12 |
12 |
26 |
175 |
166 |
125 |
9.60 |
NXT 42 - 12 |
12 |
42 |
170 |
197 |
165 |
15.70 |
NXT 65 - 12 |
12 |
65 |
174 |
350 |
166 |
22.30 |
NXT 100 - 12 |
12 |
100 |
235 |
407 |
173 |
35.50 |
NXT 150 - 12 |
12 |
150 |
240 |
557 |
172 |
50.20 |
NXT 200 - 12 |
12 |
200 |
240 |
533 |
250 |
68.40 |
. |
|
|
|
|
|
|
|
|
 |
|
SMF VRLA Range - Exide Powersafe XHD range
The Legendry Exide Torr Tubular reliability now comes maintenance free from the state of the art manufacturing line. Exide Powersafe new XHD series comes with unique GEL technology mainly for UPS application. Thesr batteries are designed with tubular positive plate and GEL Electrolyte.
Tubular Positive plates, well established for partial state of charge operation make XHD series a durable battery for deep cycling application even in heavy power cut areas. The GEL electrolyte makes it compact and maintenance free with no toppong up for life |
|
TECHNICAL SPECIFICATION |
Battery Type |
Nominal Voltage (V) V / cell |
Rated Capacity (Ah) at 27'C
20 hr 1.75V / cell |
Dimensions in mm |
Weight (kg) + 5% |
Overall Height
+ / - 3 |
Length + / - 2 |
Width + / - 2 |
HD 30 - 12 |
12 |
30 |
170 |
197 |
165 |
13.00 |
HD 45 - 12 |
12 |
45 |
174 |
350 |
166 |
19.00 |
HD 82 - 12 |
12 |
82 |
235 |
407 |
173 |
33.50 |
HD 105 - 12 |
12 |
105 |
240 |
557 |
172 |
44.00 |
HD 165 - 12 |
12 |
165 |
240 |
533 |
250 |
64.00 |
. |
|
|
|
|
|
|
|
|
 |
|
Flooded Range - Tubular Plate Exide 6EL range
Exide EL rande are manufactred as per Exide's proprietary Torr Tubular technology using one of the world's most exclusive, advanced and state of the art 'HADI' high pressure spine casting (at 100 bar) machines |
|
|
|
|
|
|
|
TECHNICAL SPECIFICATION |
CAPACITIES, WEiGHTS AND DIMENSIONS |
Battery Type |
Capacity in Ah at 27'C when discharged for
|
Approx. Battery + Weight |
Overall Dimensions
|
Nominal Monobloc Unit Voltage |
10 hr., with final Voltage of 1.75V / cell |
Filled with acid (kg) + / - 1% |
L mm+ / - 3 |
W mm + / - 3 |
H mm + / - 3 |
6EL28 |
12 |
28 |
16.72 |
260 |
173 |
240 |
6EL40 |
12 |
40 |
17.90 |
260 |
173 |
240 |
6EL50 |
12 |
50 |
19.10 |
410 |
176 |
281 |
6EL60 |
12 |
60 |
27.70 |
410 |
176 |
281 |
6EL75 |
12 |
75 |
32.23 |
410 |
176 |
281 |
6EL100 |
12 |
100 |
48.38 |
506 |
220 |
273 |
|
|
|
|
|
|
|
EXIDE EL TALL TUBULAR RANGE |
CAPACITIES, WEiGHTS AND DIMENSIONS |
Battery Type |
Capacity in Ah at 27'C when discharged for
|
Approx. Battery + Weight |
Overall Dimensions
|
Nominal Monobloc Unit Voltage |
10 hr., with final Voltage of 1.75V / cell |
Filled with acid
(kg) + / - 1% |
L mm+ / - 3 |
W mm + / - 3 |
H mm + / - 3 |
6EL120 |
12 |
120 |
63.00 |
500 |
187 |
416 |
6EL130 |
12 |
130 |
60.20 |
500 |
187 |
416 |
6EL160 |
12 |
160 |
72.00 |
500 |
187 |
416 |
6EL200 |
12 |
200 |
74.00 |
500 |
187 |
416 |
. |
|
|
|
|
|
|
|
|
 |
|
Flooded Range - Tubular Plate Exide 6EL + range
The new EL+ range are manufactures with thicker Tubu;ar Plates as per Exide's proprietry Torr Tubular technology usinf one of the world's most exclusive, advanced and state of the are 'HADI' high pressure spine casting (at 100 bar) machines. |
|
|
|
TECHNICAL SPECIFICATION |
|
|
Battery Type |
Capacity in Ah at 27'C when discharged for
|
Approx. Battery + Weight |
Overall Dimensions
|
Nominal Monobloc Unit Voltage |
10 hr., with final Voltage of 1.75V / cell |
Filled with acid
(kg) + / - 1% |
L mm+ / - 3 |
W mm + / - 3 |
H mm + / - 3 |
6E40+ |
12 |
40 |
27.69 |
410 |
176 |
281 |
6EL50+ |
12 |
50 |
30.46 |
410 |
176 |
281 |
6EL66+ |
12 |
6 |
40.70 |
506 |
220 |
293 |
6EL80+ |
12 |
80 |
44.00 |
506 |
220 |
293 |
|
|
|
|
|
|
|
EXIDE EL+ TALL TUBULAR RANGE |
|
|
|
|
|
|
Battery Type |
Capacity in Ah at 27'C when discharged for
|
Approx. Battery + Weight |
Overall Dimensions
|
Nominal Monobloc Unit Voltage |
10 hr., with final Voltage of 1.75V / cell |
Filled with acid
(kg) + / - 1% |
L mm+ / - 3 |
W mm + / - 3 |
H mm + / - 3 |
6EL100+ |
12 |
100 |
56.90 |
500 |
187 |
416 |
6EL130+ |
12 |
130 |
66.90 |
500 |
187 |
416 |
6EL150+ |
12 |
150 |
71.70 |
500 |
187 |
416 |
6EL180+ |
12 |
180 |
70.80 |
500 |
187 |
416 |
, |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|